Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. ortop ; 46(4): 444-451, 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-602353

ABSTRACT

OBJETIVO: Avaliar as características físico-químicas do enxerto bovino liofilizado manufaturado em escala semi-industrial (OrthoGen, Baumer S/A*) de acordo com protocolo previamente desenvolvido pelos autores. MÉTODOS: A caracterização do enxerto de osso bovino liofilizado foi feita por meio de microscopia eletrônica de varredura (MEV), energy dispersive spectroscopy (EDS), difratometria de raios-X, análise por termogravimetria, análise de calorimetria exploratória diferencial (DSC) e espectroscopia por infravermelho Fourier-transform (FT-IR). RESULTADOS: Ca foi o principal componente (60 por cento) encontrado nas amostras, seguido por P (28 por cento) e O (5 por cento). O tamanho médio (dp) dos poros foi 316µm (146,7), variando de 91,2 a 497,8µm, e 333,5µm (304,8), variando de 87,2 a 963,9µm com 50x e 150x magnificação, respectivamente. Picos de hidroxiapatita foram a 26ºC e 32ºC, e perda de massa foi observada entre 250ºC e 640ºC, correspondendo material orgânico e água. Duas transições de temperatura (45,67°C e 91,89°C) mostraram desnaturação de colágeno tipo I e desidratação da hidroxiapatita. CONCLUSÃO: A avaliação físico-química do enxerto de osso bovino liofilizado, de acordo com o protocolo desenvolvido em escala semi-industrial, confirma que este produto apresenta excelente biocompatibilidade, com características semelhantes ao osso in natura.


OBJECTIVE: To evaluate the physicochemical characteristics of lyophilized bovine grafts manufactured on a semi-industrial scale (Orthogen; Baumer S/A*) in accordance with a protocol previously developed by the authors. METHODS: The lyophilized bovine bone grafts were characterized by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffractometry (XRD), thermogravimetric (TG) analysis, differential exploratory scanning calorimetry (DSC) and Fourier-transform infrared (FT-IR) spectroscopy. RESULTS: Ca was the main component (60 percent) found in the samples, followed by P (28 percent) and O (5 percent). The mean (sd) pore size was 316 µm (146.7), ranging from 91.2 to 497.8 µm, and 333.5 µm (304.8), ranging from 87.2 to 963.9 µm, at 50x and 150x magnification, respectively. The hydroxyapatite peaks were at 26°C and 32°C, and mass losses were observed between 250°C and 640°C, corresponding to organic material and water. Two temperature transitions (45.67°C and 91.89°C) showed denaturation of type 1 collagen and dehydration of hydroxyapatite. CONCLUSION: The physicochemical assessment of lyophilized bovine bone grafts in accordance with the protocol developed at semi-industrial scale confirmed that this product presents excellent biocompatibility, with characteristics similar to natural bone.


Subject(s)
Biocompatible Materials , Bone Transplantation , Surgical Procedures, Operative
SELECTION OF CITATIONS
SEARCH DETAIL